PL-68 Effluent Filter 
Description

PL-68 is much more than just an effluent filter. The housing can also be used as an inlet baffle (tee) or an outlet baffle. The housing is designed to accept Polylok’s snap in gas deflector to deflect gas bubbles away from the tee and to keep the solids in the tank. 

Features
• Offers 68 linear feet of 1/16” filter slots, which significantly extends time between cleaning.PL68 Effluent Filter
• Accepts 3/4” PVC handle.
• Locks in any 360° position when used with PL-68 Tee.
• PL-68 Housing can be used as an inlet or outlet tee.
• Gasket prevents bypass.

PL-68 Installation:
Ideal for residential waste flows up to 800 gallons per day (GPD). Easily installs in any new or existing 4" outlet tee.

1. Locate the outlet of the septic tank.
2. Remove the tank cover and pump tank if necessary.
3. Glue the filter housing to the outlet pipe, or use a Polylok Extend & Lok if not enough pipe exists. 
4. Insert the PL-68 filter into tee.
5. Replace and secure the septic tank cover.

PL-68 Maintenance:
The PL-68 Effluent Filter will operate efficiently for several years under normal conditions before requiring cleaning. It is recommended that the filter be cleaned
every time the tank is pumped, or at least every three years.

1. Do not use plumbing when filter is removed.
2. Pull PL-68 out of the tee.
3. Hose off filter over the septic tank. Make sure all solids fall back into septic tank.
4. Insert filter back into tee/housing.

 

 

PL-122 Effluent Filter 
Description

The PL-122 was the first filter developed by Polylok. The biggest advantage of this filter is that it has an automatic shut off ball built into every filter. When the filter is removed for regular cleaning, the ball will float up and temporarily shut off the system so the effluent won’t leave the tank. To this day, no other manufacturer can make that claim. It is also rated for 1,500-3,000 GPD (Gallons Per Day) and is NSF approved. 

Features

  • Offers over 122 linear feet of 1/16th inch filter slotsPL122 effluent filter
  • Has a flow control ball that shuts off the flow of effluent when the filter is removed for cleanings
  • Has its own gas deflector ball which deflects solids away
  • Installs easily in new tanks, or retrofits in existing systems
  • Comes complete with its own housing; no gluing of tees or pipe
  • Rated for 1,500-3,000 GPD
  • Has a modular design allowing for increased filtration
  • Accepts 3'' and 4'' SCHD 40 and SDR 35 Pipe

The PL-122 Effluent Filter should operate efficiently for several years under normal conditions before requiring cleaning. It is recommended that the filter be cleaned every time the tank is pumped or at least every three years. If the installed filter contains an optional alarm, the owner will be notified by an alarm when the filter needs servicing. Servicing should be done by a certified septic tank pumper or installer.
Maintenance Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Do not use plumbing when cleaning filter.
  • Pull PL-122 out of the housing.
  • Hose off filter over the septic tank. Make sure all solids fall back into septic tank.
  • Insert the filter cartridge back into the housing making sure the filter is properly aligned and completely inserted.
  • Replace septic tank cover. PL-122 Installation: Ideal for residential and commercial waste flows from 1,500-3,000 Gallons Per Day (GPD).

Installation Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Glue the filter housing to the 4" or 6" outlet pipe. If the filter is not centered under the access opening use a Polylok Extend & Lok or piece of pipe to center filter.
  • Insert the PL-122 filter into its housing.
  • Replace the septic tank cover.

PL-525 Effluent Filter 
Description

Polylok, Inc is pleased to add its new commercial filter to its existing line of quality effluent filters. The PL-525 is rated for over 10,000 GPD (Gallons Per Day) making it one of the largest commercial filters in its class. It has 525 linear feet of 1/16" filtration slots. Like the Polylok PL-122, the new Polylok PL-525 has an automatic shut off ball installed with every filter. When the filter is removed for cleaning, the ball will float up and temporarily shut off the system so the effluent won’t leave the tank. No other filter on the market can make that claim! 

Features

  • Rated for 10,000 GPD (Gallons Per Day)PL 525 Effluent Filter
  • 525 linear feet of 1/16” filtration
  • Accepts 4'' and 6'' SCHD. 40 pipe
  • Built in Gas Deflector
  • Automatic shut-off ball when filter is removed
  • Alarm accessibility
  • Accepts PVC extension handle

The PL-525 Effluent Filter should operate efficiently for several years under normal conditions before requiring cleaning. It is recommended that the filter be cleaned every time the tank is pumped or at least every three years. If the installed filter contains an optional alarm, the owner will be notified by an alarm when the filter needs servicing. Servicing should be done by a certified septic tank pumper or installer.
Maintenance Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Do not use plumbing when filter is removed.
  • Pull PL-525 out of the housing.
  • Hose off filter over the septic tank. Make sure all solids fall back into septic tank.
  • Insert the filter cartridge back into the housing making sure the filter is properly aligned and completely inserted.
  • Replace septic tank cover. PL-525 Installation: Ideal for residential and commercial waste flows up to 10,000 Gallons Per Day (GPD).

Installation Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Glue the filter housing to the 4" or 6" outlet pipe. If the filter is not centered under the access opening use a Polylok Extend & Lok or piece of pipe to center filter.
  • Insert the PL-525 filter into its housing.
  • Replace the septic tank cover.

 

PL-625 Effluent Filter
Description

The PL-625 filter is ideal for grease trap applications. The 1/32” filtration has been shown to reduce fats, oils, and grease (FOG) by as much as 60% to 98%! The filter may be used in onsite wastewater systems that require a finer level of TSS removal. Whatever the application, Polylok has the filter for you! 

Features

  • Rated for 10,000 GPD (Gallons Per Day)PL 625 effluent filter
  • 625 linear feet of 1/32" filtration slots
  • Accepts 4'' and 6'' SCHD. 40 pipe
  • Built-in Gas Deflector
  • Automatic shut-off ball when filter is removed
  • Alarm Accessibility
  • Accepts PVC extension handle

Ideal For:

  • Grease Traps
  • Laundromats
  • Dog Kennels
  • Finer level of TSS removal

The PL-625 Effluent Filter should operate efficiently for several years under normal conditions before requiring cleaning. It is recommended that the filter be cleaned every time the tank is pumped or at least every three years. If the installed filter contains an optional alarm, the owner will be notified by an alarm when the filter needs servicing. Servicing should be done by a certified septic tank pumper or installer.
Maintenance Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Do not use plumbing when filter is removed.
  • Pull PL-625 out of the housing.
  • Hose off filter over the septic tank. Make sure all solids fall back into septic tank.
  • Insert the filter cartridge back into the housing making sure the filter is properly aligned and completely inserted.
  • Replace septic tank cover. PL-625 Installation: Ideal for residential and commercial waste flows up to 10,000 Gallons Per Day (GPD).

Installation Instructions:

  • Locate the outlet of the septic tank.
  • Remove tank cover and pump tank if necessary.
  • Glue the filter housing to the 4" or 6" outlet pipe. If the filter is not centered under the access opening use a Polylok Extend & Lok or piece of pipe to center filter.
  • Insert the PL-625 filter into its housing.
  • Replace the septic tank cover.

Snap together effluent filters

Filter Alarm Panel and SmartFilter™ Control Switch
Description
The Polylok™ filter alarm panel and switch provides a visual and audible notification of impending filter and tank servicing.  Our Patented SmartFIlter™ control switch attaches to Most Polylok™ Filters and All Zabel & Best Filters.  The filter alarm switch activates when the filter cartridge is near capacity on solids that have built up through the filtering process.  The filter alarm switch sends a signal to the alarm panel activating the septic tank alarm.  The owner will need to call a local septic service company for immediate service.  

 

Outdoor Smart Filter Alarm

Features

  • Complete package includes standard VRS control switch with 15 feet of cable, indoor/outdoor alarm panel, and an effluent filter
  • Alarm panel, control switch, and an effluent filters can be purchased separately or as part of a system package
  • Alarm panel features manual alarm test switch and horn silence switch
  • Alarm horn rated 82 decibels at 10 feet (3 meters)
  • Direct interface of control switch and effluent filter insures proper placement of switch
  • Alarm sounds when the tank and filter reach 90% maturity
  • For indoor/outdoor use