Biotech Industrial reverse osmosis systems

Products

  • PRODUCTS
  • Product 2
  • Product 3
  • Product 4
  • Product 5
  • Roofing Systems
  • Product 6
  • Product 7

 

 

 

Industrial Reverse Osmosis 1500 - 9000 GPD

RO1500 Reverse Osmosis System RO3000 Reverse Osmosis System RO4500 Reverse Osmosis System
RO1500 RO3000 RO4500

SPECIFICATIONS

 

PART Nr.

RO1500GPD

RO3000GPD

RO4500GPD

RO6000GPD

RO9000GPD

 

Working pressure

150 – 250 psi

Booster Pump

0,75kW / 1HP

1,5 kW / 2HP

2,2kW / 3HP

2,2kW / 3HP

3,0kW / 4HP

Membrane mat.

TFC with FRP outer wrap

Membr. Size x Units

4040 x 1

4040 x 2

4040 x 3

4040 x 4

4040 x 6

Housing material

304 Stainless steel with caps

Membr. housings

1 x SS4040

2 x SS4040

3 x SS4040

4 x SS4040

6 x SS4040

Flow meters

Pure water & waste water

Pressure gauges

Feed water pressure & Booster pump outlet pressure gauges

H2O quality indicator

TDS meter with LCD display

Electrical control

Micro-computer, overload breakers, LED indicators

Frames parts

Stainless steel main frame

Dimensions cm

50L x 43W x 120H

50L x 49W x 120H

73L x 250W x 150H

Weight

±55kg

±80kg

±100kg

±120kg

±300kg

Optional

Work Flow Process Control Panel

Pre-Filtration

2 x 20" Filterhousing 20" PP cartridge 5µ

TK 207 (20" PP cartr. 7x5µ)

Optional Softener

SO100dH

SO120dH

SO160dH

SOD120dH

SOD120dH

 

RO6000 + pre treatment reverse osmosis system

Feed water Requirements:

  • Feed water pressure                   > 40 psi
  • Feed water temperature             20 - 45°C
  • Feed water TDS                          <1000 ppm
  • SDI                                              <3
  • Turbidity                                      <1 NTU
  • Iron                                              <0,1 ppm
  • pH                                                  3 ~ 11
  • Oxidizer                                        < 0 ppm
  • Hardness                                      < 4 ppm

Appearance, outlook and configuration of the RO-installation may vary, depending on the feed water analysis.
Optional, depending on the water analysis, it may needed a more complicated pre-treatment installation, s.a. automatic particle filter, iron removal, manganese removal, hardness removal,....

RO6000 Reverse Osmosis System Diagram

Certified Water Specialist and Installer